Voluson E6




Year Launched 2009
Monitor (inch) 19" LCD
Tilt/Rotate Adjustable Monitor : Yes
Monitor Resolution : 1280*1024
Image Size Resolution
Touch Screen (Inch) : 10.4"
Trackball or Trackpad : Trackball
CP Back-Lighting : Yes
Weight (131kg)
Probe Ports : 4
Maximum Depth of Field : 30cm
Minimum Depth of Field : 0-2cm
Cart (HCU) : No
Independent Steer & Lockable Wheels : Yes
Monitor (inch) 19" LCD
Tilt/Rotate Adjustable Monitor : Yes
Monitor Resolution : 1280*1024
Image Size Resolution
Touch Screen (Inch) : 10.4"
Trackball or Trackpad : Trackball
CP Back-Lighting : Yes
Weight (131kg)
Probe Ports : 4
Maximum Depth of Field : 30cm
Minimum Depth of Field : 0-2cm
Cart (HCU) : No
Independent Steer & Lockable Wheels : Yes
DICOM 3 : Yes
DICOM SR_Vascular : Yes
DICOM SR_OB/GYN : Yes
JPEG, WMV, & AVI : Yes
USB : Yes
HDD/SDD : 450GB
DVD/CD RW : Yes
Wireless LAN : Yes(Option)
DICOM SR_Vascular : Yes
DICOM SR_OB/GYN : Yes
JPEG, WMV, & AVI : Yes
USB : Yes
HDD/SDD : 450GB
DVD/CD RW : Yes
Wireless LAN : Yes(Option)
Tissue Harmonic Imaging : Yes
Spatial Compounding(=CrossXbeam) : Yes
Speckle Reduction (=SRI) : Yes
Auto Image Opt(B mode) : Yes
Auto Image Opt(Doppler) : Yes
Write Zoom : Yes
Triplex Mode : Yes
Auto NT Measurement (=Sono NT) : Yes
Auto Follicle 2D Measurement : Yes
Auto Follicle 3D Measurement : Yes
Automated B/M/D Measurement : Yes
Automated LH Measurement : Yes
Live Dual (B/BC) Mode : Yes
SmartExam or Ease Protocol : Yes
Raw Data File : Yes
Flexible Report : Yes
Spatial Compounding(=CrossXbeam) : Yes
Speckle Reduction (=SRI) : Yes
Auto Image Opt(B mode) : Yes
Auto Image Opt(Doppler) : Yes
Write Zoom : Yes
Triplex Mode : Yes
Auto NT Measurement (=Sono NT) : Yes
Auto Follicle 2D Measurement : Yes
Auto Follicle 3D Measurement : Yes
Automated B/M/D Measurement : Yes
Automated LH Measurement : Yes
Live Dual (B/BC) Mode : Yes
SmartExam or Ease Protocol : Yes
Raw Data File : Yes
Flexible Report : Yes
2D, M mode : Yes
M-color Flow Mode : Yes
Anatomical M-mode : Yes
Trapezoidal Mode : Yes
Color, Power Angio, Pulse Wave Doppler : Yes
Bi-directional Power (=HD FLOW) : Yes
SCW Doppler : Yes
Tissue Doppler(Velocity) Imaging : Yes
Freehand 3D : Yes
Live 3/4D OB/GYN : Yes
HD Live : Yes
STIC (Spatio-Temporal Image Correlation) : Yes
B Flow : Yes
Panoramic Imaging (=Logiq view) : Yes
Contrast Imaging - Cardiac : Yes
M-color Flow Mode : Yes
Anatomical M-mode : Yes
Trapezoidal Mode : Yes
Color, Power Angio, Pulse Wave Doppler : Yes
Bi-directional Power (=HD FLOW) : Yes
SCW Doppler : Yes
Tissue Doppler(Velocity) Imaging : Yes
Freehand 3D : Yes
Live 3/4D OB/GYN : Yes
HD Live : Yes
STIC (Spatio-Temporal Image Correlation) : Yes
B Flow : Yes
Panoramic Imaging (=Logiq view) : Yes
Contrast Imaging - Cardiac : Yes
Contrast Imaging : Yes
Strain-based Elastography : Yes
Strain-based Elastography : Yes
Abdominal : Yes
Women's Health Care (GYN & Breast) : Yes
OB : Yes
Fetal Echo : Yes
Vascular : Yes
TCD(Transcranial) : Yes
Small Parts (Breast, Thyroid, Testis) : Yes
MSK/Anesthesiology : Yes
Pediatrics : Yes
Urology (Renal, Prostate) : Yes
Echocardiography_Adult : Yes
Echocardiography_Pediatric : Yes
Internal Medicine w/ Shared Service : Yes
Contrast Imaging _ General Imaging (Low MI) : Yes
Contrast Imaging _ Cardiac (High or Low MI) : Yes
Strain Elastography : Yes
Women's Health Care (GYN & Breast) : Yes
OB : Yes
Fetal Echo : Yes
Vascular : Yes
TCD(Transcranial) : Yes
Small Parts (Breast, Thyroid, Testis) : Yes
MSK/Anesthesiology : Yes
Pediatrics : Yes
Urology (Renal, Prostate) : Yes
Echocardiography_Adult : Yes
Echocardiography_Pediatric : Yes
Internal Medicine w/ Shared Service : Yes
Contrast Imaging _ General Imaging (Low MI) : Yes
Contrast Imaging _ Cardiac (High or Low MI) : Yes
Strain Elastography : Yes
Convex (1~6Mhz) : Yes
Convex (2~9Mhz) : Yes
Endocavity_Curved Type (5~8Mhz) : Yes
3D Convex (2~6Mhz) : Yes
3D Convex Light Weight (2~7Mhz) : Yes
3D Endocavity (3~10Mhz) : Yes(5~9Mhz, 120degree)
3D Micro Convex (3~9Mhz) : Yes
3D Linear (4~18Mhz) : Yes
Linear (>14Mhz) : Yes
Linear (3~12Mhz) : Yes
Linear (<9Mhz) : Yes
Linear 50mm : Yes
Phased Array_Adult (1~5Mhz) : Yes
Phased Array_Pediatric (3~8hz) : Yes
Pencil CW (2Mhz) : Yes
Pencil CW (5 or 6Mhz) : Yes
Convex (2~9Mhz) : Yes
Endocavity_Curved Type (5~8Mhz) : Yes
3D Convex (2~6Mhz) : Yes
3D Convex Light Weight (2~7Mhz) : Yes
3D Endocavity (3~10Mhz) : Yes(5~9Mhz, 120degree)
3D Micro Convex (3~9Mhz) : Yes
3D Linear (4~18Mhz) : Yes
Linear (>14Mhz) : Yes
Linear (3~12Mhz) : Yes
Linear (<9Mhz) : Yes
Linear 50mm : Yes
Phased Array_Adult (1~5Mhz) : Yes
Phased Array_Pediatric (3~8hz) : Yes
Pencil CW (2Mhz) : Yes
Pencil CW (5 or 6Mhz) : Yes
Sıkça Sorulan Sorular
1Sıkça Sorulan Sorular
Auto Optimization is a one-touch image optimization function that a user to optimize the image based on the actual B-mode image or Pulse wave Doppler data. The function works based on preset levels (Low, Medium, and High) and allows user to pick a preference for the contrast enhancement in the resulting image. Low does the least amount of contrast enhancement, high does the most. Auto Optimization is available in single or multi image, on live, frozen or CINE images (in B-Mode only), while in zoom, and in Spectral Doppler. Auto Optimization in PW Doppler Mode optimizes the spectral data. Auto adjusts the Velocity Scale (live imaging only), baseline shift, dynamic range, and invert (if preset). Upon deactivation, the spectrum is still optimized.