Lorem ipsum dolor sit amet, consectetur adipiscing elit. Fusce vitae dolor ipsum. Sed nec euismod metus. Donec lacinia lorem sapien, et accumsan massa auctor ac. Ut eget lacus vel sapien pretium viverra ut at elit. Ut id nulla lacus. Donec nec faucibus sapien. Praesent id purus sit amet neque ornare mollis vulputate sed augue. Aliquam erat volutpat. Donec purus justo, lacinia eu nunc et, ornare maximus urna.

Curabitur quis magna nisi. Praesent finibus magna consequat, tempus massa non, cursus nisl. Curabitur eget diam vel ligula venenatis maximus. Integer faucibus dignissim ex at interdum. Nam mattis massa nec suscipit elementum. Ut quis iaculis nisi. Donec bibendum cursus metus, id finibus erat congue in. Aenean mi magna, varius a condimentum sed, egestas id mi. Mauris gravida orci at odio scelerisque gravida. Cras vitae nisi sodales, porttitor tellus non, ornare velit. Ut neque velit, fermentum non nulla eu, porttitor luctus ligula. Aliquam ut facilisis lectus. Nullam at hendrerit erat.

TECHNICAL INFORMATION (PDF)
Monitor (inch) 21.5" wide screen LCD
Tilt/Rotate Adjustable Monitor Fully articulation arm
Monitor Resolution Image Size Resolution
Touch Screen (Inch) 10.4" wide LCD
Trackball or Trackpad: Trackball
CP Back-Lighting: Yes
Weight (60Kg)
Probe Ports: 3 (4th port option)
Boot-Up Time Sleep Mode (Quick Start)
Power Assistant(Battery)
Maximum Depth of Field: 33cm
Minimum Depth of Field: 0-1cm
Independent Steer & Lockable Wheels: Yes
2D, M mode: Yes
M-color Flow Mode: Yes
Anatomical M-mode: Yes
Trapezoidal Mode: Yes
Color, Power Angio, Pulse Wave Doppler: Yes
Bi-directional Power (=HD FLOW): Yes(Option)
SCW Doppler: Yes(Option)
Tissue Doppler(Velocity) Imaging: Yes(Option)
Freehand 3D: Yes
Live 3/4D OB/GYN: Yes(4D Option)
Stress Echo: Yes(Option)
B Flow: Yes
Panoramic Imaging (=Logiq view): Yes(Option)
Contrast Imaging - General Imaging: Yes(Option)
Strain-based Elastography: Yes(Option)
Tissue Harmonic Imaging: Yes
Spatial Compounding(=CrossXbeam): Yes
Speckle Reduction (=SRI): Yes
Auto Image Opt(B mode): Yes
Auto Image Opt(Doppler): Yes
Write Zoom: Yes
Triplex Mode: Yes
Auto IMT: Yes
Automated LH Measurement: Yes(Auto EF)
Live Dual (B/BC) Mode: Yes
SmartExam or Ease Protocol: Yes
Scan Assistant)
Raw Data File: Yes
Flexible Report: Yes
Gel Warmer: Yes
Abdominal: Yes
Women's Health Care (GYN & Breast): Yes
OB: Yes
Vascular: Yes
TCD(Transcranial): Yes
Small Parts (Breast, Thyroid, Testis…): Yes
MSK/Anesthesiology: Yes
Pediatrics: Yes
Urology (Renal, Prostate…): Yes
Echocardiography_Adult: Yes
Echocardiography_Pediatric: Yes
Stress Echocardiography: Yes
Internal Medicine w/ Shared Service: Yes
Surgury: Yes
Contrast Imaging _ General Imaging (Low MI): Yes
Strain Elastography: Yes
Convex (1~6Mhz): Yes(C1-5-RS)
Convex (2~9Mhz)
Mircro Convex (5~8Mhz): Yes(8C-RS)
Endocavity_Curved Type (5~8Mhz): Yes(E8C-RS)
3D Convex (2~6Mhz): Yes(RAB2-6-RS)
Linear (>14Mhz): Yes(ML6-15-RS)
Linear (3~12Mhz): Yes(12L-RS)
Linear (<9Mhz): Yes(9L-RS)
T or L shape Intra Operative (23mm): Yes(L8-19i-RS)
Phased Array_Adult (1~5Mhz): Yes(3Sc-RS)
Phased Array_Pediatric (3~8hz): Yes(6S-RS)
Pencil CW (5 or 6Mhz): Yes(P8D)
DICOM 3: Yes(Option)
DICOM SR_Cardiac: Yes(Option)
DICOM SR_Vascular: Yes(Option)
DICOM SR_OB/GYN: Yes(Option)
JPEG, WMV, & AVI: Yes
USB: Yes
HDD/SDD: 500GB
DVD/CD RW: Yes
Wireless LAN: Yes(Option)

FAQ

1FAQ
Auto Optimization is a one-touch image optimization function that a user to optimize the image based on the actual B-mode image or Pulse wave Doppler data. The function works based on preset levels (Low, Medium, and High) and allows user to pick a preference for the contrast enhancement in the resulting image. Low does the least amount of contrast enhancement, high does the most. Auto Optimization is available in single or multi image, on live, frozen or CINE images (in B-Mode only), while in zoom, and in Spectral Doppler. Auto Optimization in PW Doppler Mode optimizes the spectral data. Auto adjusts the Velocity Scale (live imaging only), baseline shift, dynamic range, and invert (if preset). Upon deactivation, the spectrum is still optimized.